Detail KYORITSU 1051/1052
KEW 1051
KEW 1052
Detection mode
RMS
MEAN/RMS (switch)
DC V
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
|±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS]
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
|±0.5%rdg±5dgt (Basic accuracy)
DC A
600.0/6000µA/60.00/440.0mA/6.000/10.00A
|±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS]
600.0/6000µA/60.00/440.0mA/6.000/10.00A
|±0.75%rdg±5dgt (Basic accuracy)
Ω
600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
|±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer
600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test
2.000V|±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance
10.00/100.0nF/1.000/10.00/100.0/1000µF
|±2%rdg±5dgt (Basic accuracy)
Frequency
10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
|±0.02%rdg±1dgt (Basic accuracy)
Temperature
-50 - 600ºC|±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions
Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Withstand voltage
6,880V/5 sec.
Applicable
standards
IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source
R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions
192(L)×90(W)×49(D) mm
Weight
Approx. 560g (including batteries)
Accessories
7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)
Tampilkan Lebih Banyak